ZCT225 Lead Wire Type Zero Phase Current Transformer phase transformation
Electrical Specification
(Customized is available)
Rated Current | 225A |
DC Resistance at 25℃ | 11±3Ω |
Dielectric Withstanding Voltage(Hi-pot) | 2500Vrms |
Output Voltage Vo | 25-30mV |
Rated Current | 225A |
DC Resistance at 25℃ | 11±3Ω |
Dielectric Withstanding Voltage(Hi-pot) | 2500Vrms |
Output Voltage Vo | 25-30mV |
The zero-sequence transformer mainly has the following applications:
- The outlet of the low-voltage side of the transformer of the low-voltage 400V system.
- Part of the feeder and motor circuit of the low-voltage 400V system.
- Cable outlet of medium voltage ungrounded system or small resistance grounded system.
- High-voltage direct grounding system transformer high-voltage neutral point bushing and neutral point grounding device.
- The main functions of various forms of zero-sequence transformers:
- The zero-sequence current transformer on the low-voltage side of the low-voltage 400V system transformer has two main functions: First, the operator detects the unbalanced current of the transformer during normal operation, which is convenient for operation adjustment. The second is to connect the zero-sequence current to the protection device of the low-voltage transformer, which is used for zero-sequence current protection on the low-voltage side of the transformer as a backup protection for the low-voltage busbar and feeder.
- The zero-sequence current transformers of some feeders and motor circuits of the low-voltage 400V system are mainly used to connect the zero-sequence current to the protection device for single-phase grounding zero-sequence current protection. It avoids the situation that the overcurrent protection of the loop makes the protection leapfrog action when the single-phase grounding short circuit does not meet the requirements of sensitivity.
- The role of the zero-sequence current transformer in the medium voltage system is mainly divided into two types: the zero-sequence current transformer of the small-current grounding system is mainly used to collect the change of the zero-sequence current of the loop when the system is single-phase grounded, and is mostly used for the grounding fault line selection device ; The secondary current access protection device of the zero-sequence current transformer of the small resistance grounding system is used for single-phase grounding current protection. Protection acts on tripping.
- The neutral point zero-sequence current transformer of the high-voltage direct grounding system is mainly used for the zero-sequence current protection of the high-voltage side of the transformer; the zero-sequence current transformer of the transformer neutral point grounding device is mainly used for the gap zero-sequence current protection.
Item | Rated Current(A) | Output Voltage Vo(mv) | Test Conditions | Over Leakage Characterstics | Temperature Characteristics -35~80℃ | Dimensions (mm) | ||
---|---|---|---|---|---|---|---|---|
Click PN For Details | ID | OD | HT | |||||
ZCT201 | 30 | 4-5.1 | lin=10mA RL=510 | -10%~0% | 10%Max | 5.9 | 16 | 6.5 |
ZCT202 | 30 | 5.1-6 | lin=8mA RL=750 | -10%~0% | 10%Max | 5.8 | 15.2 | 6.1 |
ZCT203 | 50 | 17-21 | lin=22.5mA RL=1k | -10%~0% | 10%Max | 9.2 | 21 | 7.3 |
ZCT204 | 30 | 12-15 | lin=22.5mA RL=1k | -10%~0% | 10%Max | 9.8 | 20.6 | 6.5 |
ZCT205 | 30 | 12.5-15.5 | lin=8mA RL=4.7k | -10%~0% | 10%Max | 9.3 | 21.3 | 7.2 |
ZCT206 | 50 | 17-21 | lin=22.5mA RL=1k | -10%~0% | 10%Max | 12.3 | 26 | 10 |
ZCT207 | 30 | 7.5-8.5 | lin=25mA RL=1k | -10%~0% | 10%Max | 15.4 | 29.8 | 10 |
ZCT208 | 60 | 10.2-12.5 | lin=20mA RL=680 | -10%~0% | 10%Max | 7.2 | 19.4 | 7.7 |
ZCT209 | 50 | 8-11.2 | lin=11.25mA RL=1k | -10%~0% | 10%Max | 7 | 17.2 | 7 |
ZCT210 | 50 | 8-11.2 | lin=11.25mA RL=1k | -10%~0% | 10%Max | 6.8 | 16.9 | 7.9 |
ZCT211 | 50 | 8-11.2 | lin=11.25mA RL=1k | -10%~0% | 10%Max | 10.6 | 25.4 | 8 |
ZCT212 | 60 | 10.2-12.5 | lin=20mA RL=680 | -10%~0% | 10%Max | 11 | 23.5 | 8 |
ZCT213 | 60 | ≥300 | lin=25mA RL=1k | -10%~0% | 10%Max | 9.4 | 23.8 | 12.7 |
ZCT218 | 60 | 10.2--12.5 | lin=25mA RL=680 | -10%~0% | 10%Max | 7.5 | 18.9 | 7.6 |
ZCT220 | 60 | ≥300 | lin=25mA RL=47k | -10%~0% | 10%Max | 10.1 | 24 | 11.5 |
ZCT225 | 60 | ≥300 | lin=25mA RL=47k | -10%~0% | 10%Max | 10.9 | 25.5 | 9 |
ZCT401 | 100 | 17-21 | lin=22.5mA RL=1k | -10%~0% | 10%Max | 15 | 29.2 | 10 |
ZCT402 | 100 | 6.3-7.5 | lin=20mA RL=370 | -10%~0% | 10%Max | 17.5 | 35.9 | 8.8 |
ZCT403 | 250 | 17-21 | lin=22.5mA,RL=1k | -10%~0% | 10%Max | 29 | 51 | 12 |
ZCT404 | 250 | 17-21 | lin=22.5mA,RL=1k | -10%~0% | 10%Max | 32 | 55.6 | 12 |
ZCT405 | 250 | 17-21 | lin=22.5mA,RL=1k | -10%~0% | 10%Max | 42 | 80*69 | 20 |
ZCT406 | 630 | 17-21 | lin=25mA,RL=1k | -10%~0% | 10%Max | 51.3 | 84 | 26 |
ZCT407 | 800 | 17-21 | lin=22.5mA,RL=1k | -10%~0% | 10%Max | 51 | 96*89 | 23 |
ZCT408 | 100 | 125-150 | lin=500mA,RL=150 | -10%~0% | 10%Max | 19 | 36 | 11.5 |
ZCT409 | 225 | 125-150 | lin=500mA,RL=150 | -10%~0% | 10%Max | 24 | 42 | 12 |
ZCT410 | 400 | 125-150 | lin=500mA,RL=150 | -10%~0% | 10%Max | 43 | 90*74 | 16 |
ZCT411 | 800 | 120-151 | lin=500mA,RL=150 | -10%~0% | 10%Max | 53 | 96*89 | 23 |