ZCT409 single phase zero phase current transformer factory direct sale
Electrical Specification
(Customized is available)
Rated Current | 225A |
DC Resistance at 25℃ | 11±3Ω |
Dielectric Withstanding Voltage(Hi-pot) | 2500Vrms |
Output Voltage Vo | 25-30mV |
The working principle of zero sequence transformer
Zero-sequence current maintenance works according to Kirchhoff’s current law: the algebraic sum of the complex currents injected into any connection point in the power circuit equals zero. Under normal conditions of the line and electrical equipment, the vector sum of the currents of each phase is equal to zero, so the secondary winding of the zero-sequence current transformer has no signal output, and the executive components will not operate.
When the common fault of the grounding device occurs, the vector sum of the currents of each phase is not zero.
The common fault current will cause magnetic flux in the ring core of the zero-sequence current transformer, and the induced voltage on the secondary side of the zero-sequence current transformer will cause the execution The components carry out actions, drive the tripping equipment, and convert the power supply network, so as to achieve the purpose of ground fault protection.
Item | Rated Current(A) | Output Voltage Vo(mv) | Test Conditions | Over Leakage Characterstics | Temperature Characteristics -35~80℃ | Dimensions (mm) |
||
---|---|---|---|---|---|---|---|---|
Click PN For Details | ID | OD | HT | |||||
ZCT201 | 30 | 4-5.1 | lin=10mA RL=510 | -10%~0% | 10%Max | 5.9 | 16 | 6.5 |
ZCT202 | 30 | 5.1-6 | lin=8mA RL=750 | -10%~0% | 10%Max | 5.8 | 15.2 | 6.1 |
ZCT203 | 50 | 17-21 | lin=22.5mA RL=1k | -10%~0% | 10%Max | 9.2 | 21 | 7.3 |
ZCT204 | 30 | 12-15 | lin=22.5mA RL=1k | -10%~0% | 10%Max | 9.8 | 20.6 | 6.5 |
ZCT205 | 30 | 12.5-15.5 | lin=8mA RL=4.7k | -10%~0% | 10%Max | 9.3 | 21.3 | 7.2 |
ZCT206 | 50 | 17-21 | lin=22.5mA RL=1k | -10%~0% | 10%Max | 12.3 | 26 | 10 |
ZCT207 | 30 | 7.5-8.5 | lin=25mA RL=1k | -10%~0% | 10%Max | 15.4 | 29.8 | 10 |
ZCT208 | 60 | 10.2-12.5 | lin=20mA RL=680 | -10%~0% | 10%Max | 7.2 | 19.4 | 7.7 |
ZCT209 | 50 | 8-11.2 | lin=11.25mA RL=1k | -10%~0% | 10%Max | 7 | 17.2 | 7 |
ZCT210 | 50 | 8-11.2 | lin=11.25mA RL=1k | -10%~0% | 10%Max | 6.8 | 16.9 | 7.9 |
ZCT211 | 50 | 8-11.2 | lin=11.25mA RL=1k | -10%~0% | 10%Max | 10.6 | 25.4 | 8 |
ZCT212 | 60 | 10.2-12.5 | lin=20mA RL=680 | -10%~0% | 10%Max | 11 | 23.5 | 8 |
ZCT213 | 60 | ≥300 | lin=25mA RL=1k | -10%~0% | 10%Max | 9.4 | 23.8 | 12.7 |
ZCT218 | 60 | 10.2--12.5 | lin=25mA RL=680 | -10%~0% | 10%Max | 7.5 | 18.9 | 7.6 |
ZCT220 | 60 | ≥300 | lin=25mA RL=47k | -10%~0% | 10%Max | 10.1 | 24 | 11.5 |
ZCT225 | 60 | ≥300 | lin=25mA RL=47k | -10%~0% | 10%Max | 10.9 | 25.5 | 9 |
ZCT401 | 100 | 17-21 | lin=22.5mA RL=1k | -10%~0% | 10%Max | 15 | 29.2 | 10 |
ZCT402 | 100 | 6.3-7.5 | lin=20mA RL=370 | -10%~0% | 10%Max | 17.5 | 35.9 | 8.8 |
ZCT403 | 250 | 17-21 | lin=22.5mA,RL=1k | -10%~0% | 10%Max | 29 | 51 | 12 |
ZCT404 | 250 | 17-21 | lin=22.5mA,RL=1k | -10%~0% | 10%Max | 32 | 55.6 | 12 |
ZCT405 | 250 | 17-21 | lin=22.5mA,RL=1k | -10%~0% | 10%Max | 42 | 80*69 | 20 |
ZCT406 | 630 | 17-21 | lin=25mA,RL=1k | -10%~0% | 10%Max | 51.3 | 84 | 26 |
ZCT407 | 800 | 17-21 | lin=22.5mA,RL=1k | -10%~0% | 10%Max | 51 | 96*89 | 23 |
ZCT408 | 100 | 125-150 | lin=500mA,RL=150 | -10%~0% | 10%Max | 19 | 36 | 11.5 |
ZCT409 | 225 | 125-150 | lin=500mA,RL=150 | -10%~0% | 10%Max | 24 | 42 | 12 |
ZCT410 | 400 | 125-150 | lin=500mA,RL=150 | -10%~0% | 10%Max | 43 | 90*74 | 16 |
ZCT411 | 800 | 120-151 | lin=500mA,RL=150 | -10%~0% | 10%Max | 53 | 96*89 | 23 |