ZCT506 construction of current transformer
Electrical Specification
(Customized is available)
Rated Current | 30A |
DC Resistance at 25℃ | 10±2Ω |
Dielectric Withstanding Voltage(Hi-pot) | 2500Vrms |
Output Voltage Vo | 17±3mV |
Current Transformers are mainly divided into two categories, one is called voltage transformers, the other is called current transformers, and its appearance is mainly used in the power industry.
In the power supply system, large currents and high voltages sometimes cannot be directly measured accurately with ammeters and voltmeters. It must be accurately measured after being reduced proportionally through the transformer.
The working principle of the current transformer is equal to the transformer of the short-circuit fault on the secondary side. It is used for current conversion, and an ammeter is connected on the secondary side to accurately measure the current (it can connect several ammeters in series). The secondary side of the current transformer must not be open.
Item | Rated Current(A) | Output Voltage Vo(mv) | Test Conditions | Over Leakage Characterstics | Temperature Characteristics -35℃~80℃ | Dimensions (mm) |
||
---|---|---|---|---|---|---|---|---|
Click PN For Details | ID | OD | HT | |||||
ZCT501 | 30 | 8-14 | lin=30mA,RL=1kΩ¸ | -10%~0% | 10%Max | 6.8 | 17.3 | 7 |
ZCT502 | 30 | 6.3-7.3 | lin=22.5mA RL=1kΩ¸ | -10%~0% | 10%Max | 6.8 | 18.2 | 7.2 |
ZCT503 | 20 | 7.5-10.5 | lin=11.25mA RL=1kΩ¸ | -10%~0% | 10%Max | 5.5 | 15.4 | 6 |
ZCT505 | 30 | 17-21 | lin=22.5mA RL=1kΩ¸ | -10%~0% | 10%Max | 9.3 | 20.9 | 7.2 |
ZCT506 | 30 | 17-21 | lin=22.5mA RL=1kΩ¸ | -10%~0% | 10%Max | 5 | 17 | 9.5 |
ZCT507 | 30 | 25-30.5 | lin=20mA RL=1kΩ¸ | -10%~0% | 10%Max | 6 | 18.6 | 10 |
ZCT511 | 20 | 4.8-5.1 | lin=20mA RL=1kΩ¸ | -10%~0% | 10%Max | 6.8 | 17.5 | 7.8 |
ZCT515 | 30 | 3.2-4 | lin=25mA RL=330Ω¸ | -10%~0% | 10%Max | 8.1 | 18 | 6.5 |
ZCT516 | 40 | 6.3-7.3 | lin=22.5mA RL=1kΩ¸ | -10%~0% | 10%Max | 7.1 | 17 | 19.1 |
ZCT519 | 50 | 17-22 | lin=11mA,RL=2kΩ¸ | -10%~0% | 10%Max | 9 | 23 | 8.3 |
ZCT520 | 50 | 20-24 | lin=20mA RL=1kΩ¸ | -10%~0% | 10%Max | 12 | 26.7 | 11 |
ZCT526 | 40 | 25-30 | lin=25mA RL=1kΩ¸ | -10%~0% | 10%Max | 5.8 | 19.3 | 7.8 |
ZCT528 | 30 | 7.5-12 | lin=30mA,RL=1kΩ¸ | -10%~0% | 10%Max | 9.3 | 20.9 | 7.5 |
ZCT534 | 40 | 6.4-7.5 | lin=20mA RL=1kΩ¸ | -10%~0% | 10%Max | 6.8 | 17.4 | 6.5 |
ZCT538 | 30 | 3.6-3.8 | lin=500mA,RL=150Ω¸ | -10%~0% | 10%Max | 5.5 | 15.4 | 5.3 |
ZCT541 | 50 | 12-13 | lin=25mA RL=330Ω¸ | -10%~0% | 10%Max | 9 | 22 | 8.3 |
ZCT543 | 20 | 3.5-4.5 | lin=20mA,RL=370Ω¸ | -10%~0% | 10%Max | - | - | 6.4 |
ZCT547 | 30 | 15-18 | lin=500mA,RL=150Ω¸ | -10%~0% | 10%Max | - | - | 17 |
ZCT548 | 30 | 13.2-17.8 | lin=11mA,RL=360Ω¸ | -10%~0% | 10%Max | 19 | 5 | 7.5 |