ZCT405 Lead Wire Type Zero Phase Current Transformer

ZCT405 lead wire Zero phase current transformer Electrical Specification (Customized is available) Rated Current 400A DC Resistance at 25℃ 38±4Ω Dielectric Withstanding     Voltage(Hi-pot) 2500Vrms Output Voltage Vo 17-21mV Differential Current Sensor function: When an electric shock or leakage fault occurs in the circuit, the protection action will cut off the power supply.Use: install a current transformer on each of the…

ZCT404 Lead Wire Type Zero Phase Current Transformer

ZCT404 zero phase current transformer potential transformer Electrical Specification (Customized is available) Rated Current 250A DC Resistance at 25℃ 20±3Ω Dielectric Withstanding     Voltage(Hi-pot) 2500Vrms Output Voltage Vo 17mV Two conditions for generating zero-sequence current: Whether it is a longitudinal fault, a lateral fault, or asymmetry between normal and abnormal conditions, as long as there is a zero-sequence voltage; The zero-sequence…

ZCT403 Lead Wire Type Zero Phase Current Transformer

ZCT403 PCB mounting zero phase sequence current transformer Electrical Specification (Customized is available) Rated Current 250A DC Resistance at 25℃ 50±4Ω Dielectric Withstanding      Voltage(Hi-pot) 2500Vrms Output Voltage Vo 17-21mV The three-phase wire on the primary side of the zero-sequence current transformer passes through the iron core, and the secondary coil is wound on the iron core. Under normal circumstances, because the three-phase current…

ZCT402 Lead Wire Type Zero Phase Current Transformer

ZCT402 Lead Wire Type Zero Phase Current Transformer factory direct sale Electrical Specification (Customized is available) Rated Current 125A DC Resistance at 25℃ 370Ω Dielectric Withstanding     Voltage(Hi-pot) 2500Vrms Output Voltage Vo 6.3-6.7mV The zero phase current transformer is combined with the leakage protection relay to form a leakage and ground fault protection device. The zero-sequence leakage current exceeding the set…

ZCT401 Lead Wire Type Zero Phase Current Transformer

ZCT401 Lead Wire Type zero sequence current transformer realiable supplier Electrical Specification (Customized is available) Rated Current 75A DC Resistance at 25℃ 68±6Ω Dielectric Withstanding     Voltage(Hi-pot) 2500Vrms Output Voltage Vo 17-21mV Precautions for installation of zero-sequence current transformers Most of the zero-sequence current transformers are of the through-core type, and the principle and installation are relatively simple. However, special attention…