Choose A Good Rogowski Coils

[vc_row][vc_column][vc_column_text]A Rogowski coil is an electrical device for measuring alternating current (AC) or high-speed current pulses. It consists of a helical coil of wire with the lead from one end returning through the centre of the coil to the other end, so that both terminals are at the same end of the coil. The whole assembly is then wrapped around the straight conductor whose current is to be measured. There is no metal (iron) core. The winding density, the diameter of the coil and the rigidity of the winding are critical for preserving immunity to external fields and low sensitivity to the positioning of the measured conductor.

Rogowski loops are simple and reliable inductive sensors that measure the net current through the cross-section of the loop. They can be highly accurate and insensitive to currents in nearby conductors provided they are sufficiently uniform. There are many successful applications inscience and industry.

The feature of Zentar® Rogowski Coils

应用于电流范围20~3000A • Usable current range: Linear, 20-3000A
额定0.333V输出 • 333 mVrms at rated output
窗口直径106mm,可定制 • Physical Size (inner diameter): 106mm (4.17″), Flexible
体积小,外型美观 • Accuracy: +/-1% from 30-3000A
可提供积分器 • External integrator is already if required
适用频率宽至100KHz • Special design avaliable up to 100kHz
尺寸 Dimesions

电气特性 Electrical properties

使用频率 Frequency band : 100KHz
耐压强度 Dielectric strenght: 3000Vrms/2 seconds
额定一次电流 Rated primary current: 2000A 50Hz
额定二次电流 Rated Secondary Current50mA 50Hz
饱和电流 Saturation current: ≥250A 50Hz
使用温度 Operate temperature -30~60℃ 0~80%RH
储存温度 Store temperature -35-80℃ 0-80%RH
Output Voltage Vo from Rpwgowski coil; 0- 0.01V
Output Voltage Vo from integrator: 0- 0.333V

 

积分器 Integrator


We select the OP-Amplifier whose noise and drift are very low.

安装说明 Installation specitication


1 Before the installation must ensure that the primary is no current status
2 Correct mouting of the CT is assured by a distinct sound of a click~
3 When Install CTs into circuit box, the circuit box’s main breaker should be turned off to perform.

[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column][/vc_column][/vc_row]

Share:

Facebook
X
LinkedIn
WhatsApp
Email

More Posts

CT Precison

The Power of Zero Phase Current Transformers Precision

For electrical safety in power distribution, residual-current protective devices play an indispensable role. The Zero-Phase Current Transformer (ZCT) is the core sensing component inside residual-current circuit breakers, GFCI receptacles and leakage protection power strips. Its fundamental principle is widely understood, yet its inherent unbalanced residual output frequently becomes a hidden

Xiamen ZTC Technology Attends to electronica 2026: Next-Gen Current Sensing & Keynote Session

Electronica Munich is the world’s premier trade fair and conference for electronics, bringing together leading global innovators, engineers, and decision-makers across power electronics, sensors, and embedded systems.This November, Xiamen ZTC Technology Co., Ltd. is proud to announce our third official appearance at this benchmark global event. Building on years of

How Magnetic Hysteresis Characteristics Improve Current Transformer Performance

How Magnetic Hysteresis Characteristics Improve Current Transformer Performance: Engineering Insights from ZTC

Allen Yang Marketing Engineer & Current Transformer Application Expert Helping You Select the Right CTs To Succeed Your Projects Current Transformers For Electrical Safety Current Transformers For Electric Metering How Magnetic Hysteresis Characteristics Improve Current Transformer Performance: Engineering Insights from ZTC Table of Contents Current transformers (CTs) play a critical

improve gfic stability

How Residual Output Testing Helped Improve Current Transformer Stability

Allen Yang Marketing Engineer & Current Transformer Application Expert Helping You Select the Right CTs To Succeed Your Projects Current Transformers For Electrical Safety Current Transformers For Electric Metering Table of Contents How Residual Output Testing Helped Improve Current Transformer Stability A Practical Engineering Case from ZTC For GFCI products,

Send Us A Message