ZT5S 16/32A RCD Leakage Protection Switch Wall Switch

ZT5S 16/32A RCD Leakage Protection Switch Wall Switch Electrical Specification (Customized is available) Brand Name Zentar Model No. ZT5S Rated current 16A/32A Application Air Condition, Water Heating Electrical Machine Certificate  ISO9000, ISO14000&ROHS,CCC Color WHITE Clamp times 3000 times Rated Output Voltage 230V Rated Frequency 50Hz/60Hz Trip Time ≤0.1s Dielectric Strength 2000Vrms/2 secondary between SEC./PRI. Rated…

PCT216 Precision Current Transformer

PCT216 Precision Current Transformer Electrical Specification (Customized is available) Rated Primary Current 10A Max Primary Current 80A Rated Secondary Current 5mA Accuracy 0.1~2.0 Electrical Strength 3000VAC 1mA60s Load Resistance 20Ω Rated Frequency 50/60HZ Current transformer selection points (1) The rated frequency of the current transformer should be consistent with the current frequency of the line under test. (2) Select the rated voltage of the current transformer according…

ZCT538 Pin type zero phase current transformer

ZCT538 PCB Mounting Zero phase current transformer Electrical Specification (Customized is available) Rated Current 30A DC Resistance at 25℃ 35-48Ω Dielectric Withstanding     Voltage(Hi-pot) 2500Vrms Output Voltage Vo 3.6~3.8μA The zero phase current transformer is a line fault current monitor. Generally, there is only one iron core and secondary winding. When using, the primary three core cable is passed through the…

ZCT526 Pin type zero phase current transformer

ZCT526 zero sequence current transformer principle Electrical Specification (Customized is available) Rated Current 30A DC Resistance at 25℃ 36±5Ω Dielectric Withstanding     Voltage(Hi-pot) 2500Vrms Output Voltage Vo 60-90mV When a single phase grounding fault occurs in the primary line, an unbalanced current (meaning zero phase current) is generated in the primary circuit, and a tiny current is induced in the secondary…

ZCT503 Pin type zero phase current transformer

ZCT503 Pin type zero phase current transformer supplier Electrical Specification (Customized is available) Rated Current 30A DC Resistance at 25℃ 40±5Ω Dielectric Withstanding     Voltage(Hi-pot) 3000Vrms Output Voltage Vo 7.5-8.5mV The basic principle is the same as that of ordinary transformers. The main differences are: The use methods are different. The zero phase current transformer is used to detect the zero…

CT315 Split Core Current Transformer

The CT315 600A Split Core Current Transformer, operating at 50~60Hz and withstanding up to 2000Vrms, is designed for electricity power measuring. It features a PC/ABS alloy shell, oriented cold-rolled silicon steel core, and high-strength enameled wire. The transformer is structured for both cable and copper bar installations and ensures accurate measurement with a maximum linearity error of 1%.